Symptom: After printing dozens of sheets on 80 grams of paper, the customer encountered paper jams J032 J034. Reason: Upon arrival at the site, it was observed that 20 sheets were tested and found to be flat and stuck on the PTB belt, or stuck on the fixed paper output ..
Symptom: After replacing the staples, the 81 page sorter SR5060 does not recognize them and prompts to add staples. The binding action is abnormal. Reason: The nails inside the nail box are stuck. Solution: 1. If the customer operates normally and the machine prompts that the nails are used up, replace the nail box with a new one and close the pagination ..
Symptom: PRO 8110S large paper box, single-sided and double-sided. The first side is skewed, and the second side is normal. Reason: 1. Measure the paper size to confirm that the paper itself is not skewed. 2. Use standard A3 paper to pack it in the machine. 2. Test the double-sided of the paper box and it is normal. 3
Symptom: When customers print booklets, the paper will appear J-123 before entering the paginator. After removing the paper jam and continuing to print, it will also jam and appear SC-720-40. Reason: 1. According to the on-site situation and maintenance manual ..
Symptom: The customer reported that when the machine resumed printing after experiencing a paper jam, it found that paper box 2 could not be loaded. Reason: According to the customer's description, it should be caused by the customer picking up the paper jam, and there is suspicion of shredded paper. Process: Upon arrival at the site, inspect the paper rolling mechanism ...
Symptoms: 1) Occasionally report errors and sc402-512) The printed counter page has serious bottom ash, and it is very light when printing all black documents. Figure: Reasons: 1) Due to the substandard on-site environment, next to the toilet, the humidity is generally 60...
Symptom: The startup prompt shows that the waste powder bottle is full. Reason: This is a common problem. Generally, cleaning the rear waste powder bottle full sensor will restore it. However, in this repair, while cleaning the sensor, the front waste powder bottle will also be filled with the sensor (also cleaned)
symptoms: boot no response cause: ac drive board fu401 fuse blown, PSU-A board damage to the resolution process: 1, boot no response, by looking at the circuit diagram can be judged by the ac drive board CN408...
Symptoms: Code SC513-11, indicating 1-3 carton failure and double-sided unit failure. Causes: TE mobile unit in-situ sensor is dirty and blocked by paper wool. solution: 1. ask how the customer fault, customer feedback in print...
Symptom: Power-on self-check error SC513-01 reason: sensor dirty induction bad solution: shield the two front doors to close the sensor, open the front door to observe the left and right movement of the alignment component during the self-check process, and judge that the alignment movement motor is positive...