Symptom: Code SC513-11, indicating 1-3 paper box faults and double-sided unit faults
Reason: The in-situ sensor of TE mobile unit is dirty and covered by paper wool.
Solution:
1. Inquire with the customer about how the malfunction occurred. The customer reported that there was a sudden malfunction during printing, and there were no issues such as paper jams or abnormal noises. During normal operation, this situation suddenly occurred, and sometimes it can be used again after restarting. However, it may occur again when printing, ruling out the possibility of paper shredding in the double-sided unit.
2. Query manual code SC513-11 (the trailing edge moving unit is the TE moving unit in the manual)
3. Upon inspection of the TE mobile unit, it was found that it had returned to its original position without any issues. The in-situ sensor was removed, and it was discovered that all the paper hairs on the TE in-situ sensor were obstructed. After cleaning the sensor and reinstalling it, the machine was turned on for testing, and the fault disappeared. The test printing was normal.
The sensor is located under this cover plate.
Clean this sensor.
Precautions for disassembly and assembly:
When disassembling, the locking plate of the moving unit pulley must be installed, which may cause a change in the position of the alignment gear.
2. After installation and reset, check whether the position of the alignment gear has changed due to the inspection of the alignment moving unit. After the change, it will report SC512-00 or paper jam J031. Reset it promptly after the change.
Tags: #SC513-11 #8100 #8120 #TE Mobile Unit #Home sensor dirty