Ricoh 8100 waste powder bottle full quick determination problem summary

Come back soon. 370 0

Symptom: Startup prompt shows that the waste powder bottle is full


Reason:

This is a common problem. Generally, cleaning the rear waste powder bottle to fill the sensor will restore it. However, in this repair, after cleaning the sensor and swapping it with the front waste powder bottle to fill the sensor (also cleaned), the fault still exists.

1. Check the waste powder full sensor in SP5803-182 and manually rotate the waste powder conveyor motor, which will cause a 0-1 change

2. SP5803-183 checks that the waste powder bottle is about to fill the sensor, and there is no change in the paper cover inspection. The machine keeps indicating that the waste powder bottle is about to be full (it has actually been emptied), indicating that there is a problem with the sensor.

After replacing the sensor, the prompt for the waste powder bottle to be full will disappear, and SP5803-183 will return to normal status

However, the machine still prompts that the waste powder is full, and the fault persists.

5. Reviewing the operating principle of the institution, after the waste powder bottle conveying motor is started, the waste powder full sensor will be alternately shielded, and 0-1 will change back and forth. The machine will prompt whether the waste powder is full based on this situation

6. When opening and closing the door of this machine, there will be a self-test action. When the front door is open (to prevent the scrap powder from being full), enter SP5803-182, close the door and observe the sensor changes. It was found that the sensor remained in the 1 state, but it changed when manually rotating the cover before. To be safe, the sensor was replaced and tested, and the machine returned to normal. Further diagnosis SP5803-182 confirms that during the self check of closing the door, 0-1 does indeed alternate multiple times. At this point, it can be determined that the faulty sensor is not sensitive. It can still transmit signals when manually rotated, but it cannot provide timely feedback signals when quickly covering back and forth.


Solution:

Both sensors have problems with this malfunction, so it will be a bit complicated to handle. When encountering such problems, it is recommended to open the front door and enter SP mode SP5803-182, then close the door and observe whether the sensor can alternate and change multiple times during self inspection. If not, it can be basically judged that the sensor is dirty or faulty. Also, check whether SP5803-183 is normal, and then proceed with further processing.