Symptom: When scanning to FTP, a Ricoh IMC2010 may experience direct copying. Possible reasons include controller/setting issues. Repair process: 1. Check the fault situation on site, and after FTP scanning, the machine will not have any issues ..
Symptom: An M2700 machine encountered scanning failure during the operation of scanning folders, with the display screen reporting a "server response error". Possible causes of malfunction analysis: 1. SMB protocol in the Windows system of the user's computer ..
Symptom: A Ricoh IM2500 cannot open files after PDF scanning through the panel USB interface. Fault screenshot: Possible causes: setup issues/software issues/firmware issues/network issues/board issues/chip issues ..
Failure phenomenon: the customer reported that there was a problem with scanning after moving: the two systems printed normally, the scanning to Windows system was normal, and the scanning to apple system failed (the settings of apple system were normal before moving). the customer asked apple system for after-sales support...
Fault phenomenon: When scanning a small number of original documents or a few original documents, it prompts insufficient memory. Reason for job deletion: Our MFP scans the default file type set to compact PDF, which means that the PDF format needs to be compressed into smaller compact files ..
When scanning to a shared folder using the 2014 series machine settings, the machine prompts "server response error" and cannot scan. In the same network environment, there are other models of Ricoh machines that can use SMB scanning normally. The same computer, the same ..
The computer can ping the printer, but the printer cannot ping the computer. The computer can print but cannot scan shared folders. Other computers can scan. Using the ping command, the computer can ping the printer, but the printer cannot ping ..
What is the Scan to Folder Configuration Tool? [Video] Ricoh Shared Folder Open Tool STFConfTool Usage: Scan to Folder Configuration Tool is a support tool that can help customers easily set up scanning on MFPs ..