The copying and printing of the machine are normal, but as long as the machine is opened, the fault code SC663-00 will be reported, and the machine can be used normally after restarting. The maintenance process can be used normally: 1. Prompt according to the fault code; Replacing the IO board and plugging and unplugging the wiring harness again failed, and the fault was not arranged...
Symptoms The machine is equipped with Streamline NX software. After starting up, the screen displays "Please wait a moment while starting Streamline NX". Since then, the machine has been displaying this interface diagnosis process 1) The screen is displaying the above boundary...
Symptoms: machine boot screen does not show, the machine no action. Reason: bad power supply board; Bad motherboard and control board; Poor repair process of power switch wiring harness: 1. As there is no display on the screen and the rear cover plate is disassembled, the motherboard and control board are found....
Symptoms: A SPC352DN machine has a startup display SC641-04, and the failure of replacing the new controller board and engine board is still the same. Reason: The communication error between BCU and controller board is tried to pass through BCU three times...
Epson WF-8093,WF-8593 disassembly and installation video WF-8093 disassembly and assembly video-installation-print head ink tube installation WF-8093 disassembly and assembly video-disassembly -1) Rear ASF Docum...
Symptoms The machine has a SC665-05 malfunction after startup. Cause Maintenance Process On-site Maintenance Measures: 1) Disassemble and inspect the BICU board, imaging IOB board, paper transfer IOB board and PSU board related connection wiring harness. start the machine detection so...
For the preliminary judgment method of symptom color machine model board, please refer to the following steps to execute and use. Maintenance process explanation Met-MF3yzabcel(IM C2000/C2500/C3000/C3500/C4500...
Symptoms: The SC240-02 fault code (Figure 1) occurred after the laser unit of an IM C6000 model was disassembled and assembled, which cannot be eliminated. Maintenance process: 1. Since the equipment was normal before, damage to other parts was not considered. Heavy...
Symptoms: After the machine is MP3055SP shut down, the LED lights on the screen cannot be completely extinguished for half an hour. Reasons:[*] Poor power board and control board [*]SOP screen settings. Poor maintenance process: 1. According to the fault display, replace the electricity in turn...