Symptoms The machine is equipped with Streamline NX software. After booting up, the screen displays "Starting Streamline NX, please wait", and the machine continues to display this interface thereafter Diagnostic process 1) When the screen displays the above interface, it cannot enter user tools and SP mode. If the SOP screen is replaced, the fault still persists. 2) Replace the controller board, but the fault persists. 3) Replace the IPU board and BCU board separately, but the fault persists. 4) Replace the white flat cable between the IPU and BCU, but the fault persists. 5) Replace the NVRAM chip, but the fault persists. [kkpay=5] 6) Replace the power board and solve the problem. Upon inspection, it was found that the R9 and R10 resistors on the power board were burnt.
Solution Replace the power board and solve the problem. [/kkpay] |
Tags: #BCU board #NVRAM #Power board #2500 #3500