Ricoh IM C2000 color machine model board preliminary judgment method

Visitor 380 0
Symptoms
Please refer to the following steps for the preliminary judgment method of the color machine model board.
Maintenance process
Explain Met-MF3yzabcel (IM C2000/C2500/C3000/C3500/C4500/C6000/M C2001).
Explaining boards: PSU (power board), BICU (basic engine control board), EngineIOB (engine input/output board), TransportIOB (paper input/output board).

Note: A multimeter is required during the judgment process.

1、 PSU: including AC PSU and DC PSU
AC board, DC board, DC PSU


1. Communication board AC PSU
1.1. Receive AC 220V voltage and send AC 220V to DC PSU of DC board, AC 24V, 5V to TransportIOB, BICU.
Note: The output of the AC PSU on the AC board is not immediately available when the power is plugged in and turned on. Feedback is required for output, so it cannot be used to determine whether the AC PSU on the AC board is functioning properly.

1.2. Measurement method for AC PSU of communication board:
Measurement during power outage:
1) Fuse measurement: Components marked with FU (the following is the appearance of the fuse). A circuit breaker indicates an abnormality.
Attention: The damage to the Class A fuses mentioned above is mostly caused by high external voltage control. Therefore, it is possible to replace the fuses and test them again after turning on the device. However, the front door should be opened when turning on the device to avoid further damage to other cards caused by the damaged card.
The damage of the B-class fuse mentioned above indicates that the board has been damaged.
2) Measurement of transistor: Components with Q markings, especially those fixed on heat sinks. If all three pins are connected to each other, it means that the transistor is damaged and the circuit is abnormal.

Measure when opening the front door and turning on the power:
Measure the AC 220V power supply from the AC power board AC PSU to the DC power board DC PSU. CN988 on the AC power board AC PSU:
There is an AC 220V output, and the AC PSU has preliminarily ruled out the possibility of malfunction;
No AC 220V output, AC PSU damaged.
2. DC power board DC PSU: Measure after opening the front door and powering on the device
2.1 After receiving the AC 220V output from the AC PSU, the DC PSU converts it into DC 5V, 12V, and 24V. The DC 5V is used to power all the boards, sensors, and switches inside the machine, while the DC 12V and 24V are used to power all the motors and electromagnets inside the machine.
2.2. Measurement method for DC PSU of DC power board:
1) Measure CN901 on DC PSU (receiving AC 220V supplied by AC PSU, as shown in the above figure):
There is an AC 220V input, and the wiring harness from AC PSU to DC PSU is connected normally;
No AC 220V input, damaged wiring harness from AC PSU to DC PSU or AC PSU.
2) Measure the outputs of CN912 and CN911 on the DC PSU: Only measure the DC 5V, and only output the other DC 12V and 24V when all units are properly positioned.