I didn't take detailed photos of the malfunction during the repair process because my hands were too dark. Print a light sample as shown in the picture to avoid wasting paper during maintenance. Folding it up, opening the door and inserting it. Running in SP mode, the 2223 VT value was found to be around 3.8, exceeding the target ..
Symptoms: IM2500 print, copy images appear shallow situation analysis process: 1. check the SP3-031, the display result is 1, indicating that the initialization is successful, check the SP3-210(TD sensor output) the result is 2.7...
Symptoms detailed: Ricoh MPC5503 prints red font with uneven color and color deviation. Fault diagnosis: In maintenance mode, use 2109 to test and print full-color samples of the red drum, and determine that the aging of the red drum is caused by uneven powder on the developing chamber. Wei ..
Preface What should we do when facing a machine failure?[*] What should we do first when encountering a failure?[*] What should we do after finishing the first step?[*] What should we do after solving the failure?[*] Strong self-confidence...
iR-ADV C5235iR-ADV C5240iR-ADV C5250iR-ADV C5255 [Fault Description] The overall color of the printed color image is lighter. [cause of failure] secondary transfer roller base...
iR-ADV C3320iR-ADV C3325iR-ADV C3330iR-ADV C3320L similar CAD file output copy of the countermeasures when the color is lighter. [fault description]...
The printing color is normal, but the copy is relatively light; There will be a black line when copying with a document feeder, but there is no black line when copying on a glass table. This content is hidden by the author. Ricoh/Christie, Ricoh copier repair ..
The black image is light. The fault sample is shown in the following figure. MP_C2003_2503_2011 diagnostic process 1) Both copying and printing have the above-mentioned faults, which should be around the drum or in the laser section. 2) Clean the hexagonal prism and color blocking inside the laser unit ..