The black image is light. The fault sample is shown in the following figure.MP_C2003_2503_2011
Diagnostic process 1) Both copying and printing have the above-mentioned faults, which should be around the drum or in the laser section. 2) Clean the hexagonal prism and color blocking glass inside the laser unit, but the malfunction persists. 3) Due to the fact that only the black image has the above-mentioned malfunction, the black image transfer roller in the ITB unit was checked and found to be functioning normally. However, the malfunction persisted even after reinstallation. 4) After replacing the black PCDU unit, the fault was resolved, and the cause of the fault was within the PCDU unit. 5) Replace the black PCU and black developing unit separately for testing, and the fault persists. 6) When replacing the parts, it was found that the metal connection plate inside the black PCDU rear shell was deformed, resulting in poor contact. After adjusting the deformed metal plate, the machine returned to normal. Adjust the parts as shown in the metal sheet in the following figure:
Solution After adjusting the position of the metal connection pieces inside the black PCDU casing, the image is normal. |
Tags: #2011 #2503 #2003 #Light color