Symptom: When printing the DX4640PD integrated mechanical version, there are white patches on the image. After cleaning the thermal head, the fault was eliminated, but after a period of operation, the fault phenomenon reappeared. The reason is poor grounding of the machine, which leads to static electricity accumulation in the thermal head and affects image plate making ..
Symptom: When printing double-sided on the DX4640PD all-in-one machine, there is a slight crease on the paper head, but single-sided printing is normal. Reason analysis 1. Check the machine settings and confirm the paper width setting of the double-sided unit paper guide to avoid incorrect paper size settings ..