When the computer printed, it was very shallow and could hardly see the words clearly, but the copying handwriting was clear. At that time, the computer installed the driver instead of the official website provided by the official website and the driver of the official website still failed. Finally, it was found that the powder saving function was turned on in the printer settings of the machine, and the concentration was normal after turning off....
The SD card is used to update the controller firmware. Set a folder "Model Name" (for example, "D161") on the SD card. will update the file renamed to "d161 *****.brn", and in the sd card of the relevant text...
MP 2001SP/2501SP symptom: Failed to successfully upgrade the firmware of the machine and crashed. Diagnostic process: 1. After on-site inquiry, upgrade the firmware of the engine, system, and operation panel of the device. When upgrading the operation panel ..
Symptom: The MP2501SP controller board is damaged; after replacing the controller, SC995-03 error is reported. Analysis of the reason: found through other models manual SC995-03 CPM setting error 3 machine serial number (11 digits...
For the MP 2001 / 2001L/2501L, if the paper and original are placed at a 90-degree angle, the leading-edge alignment setting should not be used for the vertical orientation of copy or print jobs. reasons if paper and original 90 degrees placed, figure...
MP2001SP/MP2501SP/MP2001L/MP2501L Symptoms: SC672-11 error codes appear when the machine is turned on. maintenance process: 1, maintenance manual did not query to the SC672-11...
Symptom MP2501L: The screen goes black immediately after startup, and the machine does not respond. The fuse on the power board burned out, as shown in Figure (1). Reason analysis 1. Based on the above phenomenon, it is judged that the machine has a short circuit. 2. Use a multimeter to check for short circuited components and lock the fixing sheet ..
Symptom DF: Poor paper alignment in the input and output sections. Reason: Sometimes, the paper tray cannot stop the paper at the target position. Paper hardness and external environmental influences. Solution on-site: Install the baffle and Mylar (see steps below) ***. ..
MP2001L_2501L_2001SP_2501SP_1813L_2013L Symptoms: SC120 code appears upon startup. The machine does not have ADF. Diagnostic process: Check the SC code for the following explanation: ..