Symptoms The MP2501L screen goes black at startup and the machine has no response. The fuse on the power board burned out, as shown in Figure (1). Cause analysis 1, according to the above phenomenon to judge the machine has a short circuit phenomenon. 2. Use a multimeter to check for short circuited components and lock the fixing unit. The position where the copper sheet arches and the hot roller is short circuited is shown in Figure (2). Restore the copper sheet to its installation position. See Figure (3) 3. Remove the connecting copper plate fastening screw of the lamp wire. It is found that the copper plate has a large deviation from the installation position, as shown in Figure (IV). Therefore, it is judged that someone has removed or installed the lamp holder. However, the above-mentioned failure is caused by careless operation when removing the lamp holder and moving and connecting the copper sheet, resulting in arching of the copper sheet from the clamping head of the limit (see fig. 2) and short-circuiting with the hot roller under the power-on state. Solution Repair or replace the power board, and replace the relevant components of the fixing unit. Link: https://pan.baidu.com/s/1dA83B0ud17eqSmYKd3gfow Extraction code: 1uw2 Note: The short circuit of the fixing unit has a high chance of causing damage to the high-voltage power board, and further judgment needs to be made based on the on-site situation. |