Symptom: After using the machine for a period of time, the occasional print density is light and the image is incomplete (see the figure below), and printing more than 10 pages of images continuously does not improve. Analysis and solution: Due to occasional light and incomplete print image density during use, and continuous printing ..
Symptoms When HQ9000 is turned on, it shows that the "D" part is not entering the plate properly, the plate paper cannot reach the apex position, and the code detection plate making part sensors (plate paper edge and card plate detection sensors) are normal. cause analysis 1. on-site inspection found into the version of the process...
Symptoms DD5450 plate making is normal. When printing starts to reach about 30 sheets, the plate paper starts to wrinkle. cause analysis 1, a preliminary judgment of the installation of loose steel mesh or steel mesh cracks lead, but after checking the steel mesh excluded..., Ricoh/kistar...
Ricoh DD3344C displays "wrong paper tray settings" when turned on. Reason: The placement switch of the plate making unit was not triggered. During the maintenance process, there are 2 sensors placed in the plate making unit of this model (15, 10 in the figure), among which sensor 15 is placed ..
E-00 failure on display after machine plate making. Reason 1: Defect in the machine’s MPU motherboard. 2) Defect in the machine’s wax paper tray drive. 3) Defect in the machine’s wax paper tray sensor. 4) machine wax paper clip motor...