Symptoms: There is abnormal noise during the operation of the machine, which is preliminarily judged as the abnormal noise generated by the powder adding mechanism. Analysis reason: the powder adding mechanism used by the color machine is divided into two parts, one part is to add the powder from the powder bottle to the storage hopper, and the other part is to add the toner from the storage hopper....
Symptoms: MP5055 machine, replaced the waste powder box, abnormal noise after a period of use. Analysis of causes and measures: 1. Check the waste powder box, the gear has no signs of wear, and there is no abnormal noise when rotating manually; 2. Remove the waste powder box and look from the front to the back. No abnormality is found...
MP3055, abnormal noise was found after changing the set of drums. After checking our platform, we shared that it was the bearing behind the drum. After checking and changing the bearing, it was normal to use the old drum. Therefore, the upper and lower parts of the new drum and the old drum were assembled back and forth and found to be new...
Fault description: The customer sent M176 for repair, which makes abnormal noise when starting up and is not ready. Solution process: Based on the recent malfunction of the same machine, consider the problem of abnormal noise during startup, which is basically due to the improper engagement between the belt and the idler wheel. As shown in Figure 1. ...
Fault description: The printer fails to come ready after power-on, and an abnormal noise is heard during startup. After running for a period of time, the display panel showed error 59.C0. Troubleshooting process: The user brought the printer in for repair, reporting that it could not print properly upon startup and was making unusual noises. power test found a...
iR-ADV C7580/7570 [FAILURE] The scan unit rattling when moving. [Cause of Failure] The sealing strip on the back of the original glass is half off, jamming the moving scanning unit. [Maintenance Measures] Temporary Countermeasures are to use double...
The new unpacking printer M706n is added with a 500-page paper box. After a few seconds of POST, the paper box 3 will issue "click, click, click..." Abnormal sound, the machine has strong vibration sense encountered this situation, at this time almost all users will be startled, and then immediately...
HP CP1025/M175/M176/M177 Abnormal Sound or Not Ready Trouble Phenomenon: Abnormal Sound at Start, Not Ready. troubleshooting process: recently met M176/M177 abnormal sound or not..., dimension...
After receiving the machine, the startup test prompted the concentration sensor to be wrong. After turning on the machine, it was found that the customer was using a substitute consumable black toner cartridge with powder leakage. After taking out the toner cartridge to clean the powder leakage and cleaning powder concentration sensor, the machine did not report the error. How many times did the computer print...
Phenomenon: When the machine makes abnormal noises, the following methods can be used to identify the source of the problem. Repair process: 1 Enter 218 maintenance mode and execute SP1-153-1. At this time, the machine will run the fixing motor at idle speed for 60 seconds. 2....