HP CP1025/M175/M176/M177 abnormal sound or not ready to deal with the problem

Visitor 362 0
HP CP1025/M175/M176/M177 abnormal sound or not ready to deal with the problem
Fault phenomenon: abnormal startup noise, not ready.                                       

Error process:
The recent issue of M176/M177 abnormal noise or lack of readiness is that the belt is not properly engaged with the idler wheel. As shown in the figure.

Error process:
Remove the spring that is holding the belt, separate the belt from the idler wheel, block the rear door sensor, start the machine normally, and slowly push the belt back to its original position when the engine rotates, allowing the gear to automatically engage. If it does not engage, repeat the test several times. as shown in the figure

Link: https://pan.baidu.com/s/1N75LBKntFIBC33f64rLEIA
[kkpay=5]Extraction code: q560[/kkpay]

Tags: #CP1025 #M175 #M176 #M177 #Abnormal noise