Symptom: Unable to detect the size of the original manuscript when using the manuscript table for copying. ”The analysis process is shown in the following figure: 1. Use the output to check and test the cover sensor, and it is normal. 2. The paper box was designated for A4 horizontal feeding test, but the fault persisted. 3. Check the original manuscript and discover ..
Symptom M2701: When using the document feeder to copy A4 paper, the machine cannot detect the size of the original manuscript properly. Repair process 1. When using the document feeder for copying, the MFP cannot recognize the size of the original document, but it works normally when using the document table; 2. After investigation, it was found that replacement is needed ..
Bizhub C360i: The glass surface cannot detect the original size<detailed condition>After closing DF, the 20 degree sensor displays 0>1>0. Press and hold the sensor with your hand to display 0>1, then release your hand ..