Ricoh M C2000 is unable to detect the size of the original manuscript when using a copying table

Visitor 367 0
Symptoms:It is not possible to detect the size of the original manuscript when copying on the manuscript table. ”See the following figure


Analysis process:
1. Use the output to check and test the cover sensor, it is normal.
2. The paper box was designated for A4 horizontal feeding test, but the fault persisted.
3. Upon checking the original manuscript, it was found that the paper had some curled edges due to humid air. After organizing and testing the paper, the fault disappeared.

Solution:The machine works normally when copying on a flat sheet of paper on the manuscript table.
Note: Due to differences between the MC2000 original size sensor and other models, the original size sensor is divided into a transmitter and a receiver to detect paper size.
Its working principle is that when the cover sensor is triggered, the transmitter sends a signal to detect the size of the original document. Due to some warping of the edge of the original document, the sensor cannot detect the edge of the paper during detection, resulting in the inability to recognize the size of the original document.

Tags: #C2000 #Cover plate sensor #Paper box paper #Original size #receiver