Symptoms During the copying process of an IMC2000 machine, there is a phenomenon of image stripes appearing in the copy, which are shallow and fixed in position. (As shown in the figure below) Reason: Based on the analysis of the image sample, it is preliminarily determined that the issue is with the carrier on the drum surface or developing roller of the PCDU. Through exchange testing, it is basically confirmed that it is a problem with the magenta PCDU drum unit. After disassembling the developing unit, it is confirmed that foreign objects have entered and blocked the developing stirring spiral tube, causing uneven distribution of carrier and toner on the developing roller, resulting in white stripes on the copy during printing. Maintenance process: 1) Enter SP mode and select SP2-109-003, then SP2-109-005 (1: Full color, 2: Blue, 3: magenta), 4: Print full format test pages in four different colors (yellow, 5: black). 2) Check the test page and confirm that there is a white bar on the magenta test sample. Check the magenta PCDU unit. 3) Check the rotation of the magenta PCDU unit and confirm that the load is normal. Disassembling the developing unit revealed uneven distribution of carrier and toner on the developing roller. (See the figure below) 4) Continuing to disassemble the developing unit, it was discovered that a jamming spring had entered the developing stirring spiral tube (as shown in the figure below). 5) After removing the foreign object jamming spring in the developing chamber according to the on-site situation, reinstall and test the printed copy to ensure normal operation. Link: https://pan.baidu.com/s/17-dQyCiXFYdtUfLmIpbMRw Extraction code: izx5 Solution Remove foreign objects from the developing stirring spiral tube. |
Tags: #C2000 #c6000 #Image light stripes #Developing roller #Carrier