Strangely, when the repairman used regular paper for nozzle inspection, they were able to complete the printing task normally, and then conducted relevant tests on the lower paper feed without any errors. Therefore, we tried to combine various usage methods for testing and found the following pattern: ..
Troubleshooting process: 1. Following the repair manual’s instructions, the scan unit and motherboard were replaced, but the fault persisted. 2. Unplug the trolley unit cable, troubleshoot, refer to the maintenance manual for comparison of the trolley cable, and find that ③ and ④ connections are plugged in reverse, and the fault occurs after correct connection...