Fault phenomenon: Machine error "093-92X" when turned on, low toner concentration. Solution: When using original toner, the machine detects a low toner concentration in the developing chamber and cannot replenish the toner. 1. When turned on, open the back cover ..
Failure phenomenon: Due to the use of inferior powder, the carrier is missing, which is easy to cause the copy to be weak or even the 092-651 fault code. It can be repaired by adding the carrier. The method of adding the carrier is introduced below: The solution: The steps are as follows: 1...