Troubleshooting process: 1. Following the repair manual’s instructions, the scan unit and motherboard were replaced, but the fault persisted. 2. Unplug the trolley unit cable, troubleshoot, refer to the maintenance manual for comparison of the trolley cable, and find that ③ and ④ connections are plugged in reverse, and the fault occurs after correct connection...