Symptoms: IMC6000 users find that the machine has not been able to recognize black toner and replace another new toner when replacing toner because the machine has no powder. On-site maintenance, enter maintenance mode, 3-100-001 close...
Symptom IMC2000 purchased a dual paper box unit PB3300, but an error message appeared when turned on: "The lid is open, close the indicated lid", which cannot be eliminated. Repair process: 1. Test by entering code SP5803-217 ..
Symptom: MP3055SP shows that the cover is open after turning on, but does not indicate which part of the door is open, making it impossible to perform the corresponding inspection. Reason 1: Door switch malfunction; 2. Sensor malfunction; 3. BUC board malfunction; 4. Power board malfunction ..