During the operation of IM430 and P501 symptoms, the "B" position (alignment) paper jam occurs after the paper feed in the paper tray reaches the fixing section, and the paper feed in the manual paper feed tray is selected to be normal. Maintenance process 1. As the paper feed of the paper tray is normal, the alignment sensor fault is eliminated....