Symptoms: IMC2000 the problem of inaccurate alignment of local prints. Maintenance process of faulty sample sheets: 1. Inspection found that the printed products were normal, and only there was inaccurate color matching during copying. Careful observation found that the problem of inaccurate color matching was not the whole page...
Symptom failure: MP2555 reports SC144. After replacing the scanning unit (SBU), IPU (image processing board) and BCU (basic engine control board), the error is still reported. The maintenance process corresponds to the scanning unit (SBU), IP...
MP2555 reports SC144. After replacing the scanning unit (SBU), IPU (image processing board) and BCU (basic engine control board), the error is still reported. The maintenance process is now receiving the relevant report, which corresponds to the scanning unit (SBU)...