Symptoms 1. 8100se installation, install A4 copy paper before formal printing, suddenly report code sc320-00 during preheating, manual explanation: developing bias leakage 2. On site implementation operation and results: a、 Restarting the machine - the fault persists, shutting down - opening the front door - turning on - no code reported - closing the door - machine self-test - sc320 code alarm (Figure 1), b、 No abnormalities were found during the inspection of the drum, drum cleaning, charging, and developing chamber unit. After reinstallation, the startup fault still persists, c、 After receiving phone support from Teacher Li, the test was conducted: disconnect the plug labeled as B for the output developing bias voltage in the CGB power supply component (Figure 2) (Figure 3), open the door - turn on - no report - close the door - machine self-test - sc320 still works d、 Measure the connection wire between the plug of CGB power supply component B and the developing unit, and ensure that the conductivity is normal, e、 Recheck the contact point between the rear plug of the developing unit and the developing bias spring, and no abnormalities were found. After installing them all back into the main unit, open the door, turn on, do not report, close the door, perform machine self-test - sc320 fault still persists
Reason CGB power component failure Solution: After replacing the CGB power component and turning on the machine, it worked normally and the fault was resolved. |
Tags: #8100 #sc320 #Developing bias leakage #Power component #8120