Symptom: 8300 report code SC513-02, push-pull drawer unit, can print normally after restarting the machine. According to SP7403, the last ten codes have all been SC513-02, indicating a relatively frequent occurrence. Reason: 1. Fault caused by overload of the positioning unit 2. Align and move the in-situ sensor 3. Align the mobile motor 4. Poor IOB or DRB Solution: 1. Since the machine can print normally after restarting, first exclude the IOB and DRB boards. 2. No abnormalities were found in the alignment unit, drive gear, and motor. [kkpay=5] 3. The disassembly and assembly of the alignment unit is quite complicated. It was found that the alignment movement in-situ sensor could be observed from the side by removing the second rotation unit. Therefore, the alignment movement in-situ sensor was cleaned from the side by blowing a balloon.
[/kkpay] Upon observation, SC513-02 did not appear during printing, and even after several days of observation, SC513-02 code did not appear, indicating normal printing. |
Tags: #8300 #SC513-02 #8310 #Positioning mobile motor