Symptom: The device has a self check action when turned on, and there is temperature during the fixing process. An error is reported during the self check. Reason: The possible reasons for the malfunction caused by the manual inquiry are as follows:;
Solution: On site troubleshooting process: 1. When swapping with other colored PCUs, the fault code remains unchanged. 2. Check the contact points between the PCU and the rack and replace the yellow contact points, but the fault persists. 3. The fault persists even after connecting the HVP-TTS and HVP-CB lines on the plug-in board. 4. Fault repair after replacing HVP-CB separately.
Measure: Replace HVP-CB board Note: Upon further observation of the faulty HVP board, it was found that there was a yellow dampness phenomenon. Fault analysis: The customer's equipment is used in a warehouse with a poor operating environment, and it has been stored together with a water dispenser for a long time, which has caused the board to become damp and malfunction. |