Ricoh Pro8300 black-and-white machine is easy to report SC450 and sc460 solutions in winter. Pro 8300s/8310s/8320s Pro_8100se_8110se_8120se Symptom: The 8 series black and white machine is prone to reporting SC450460 leakage problems in low temperature and low humidity environments Reason: Customers in the northwest region often report SC450460 leakage in low temperature and low humidity environments during winter. Replacing the bias rod can improve, but the maintenance time is relatively short. Solution: After removing the bias rod, wrapping the metal rod at both ends of the bias rod with electrical insulation tape twice and then reinstalling it can better solve the code problem of 450460.
|
323
0
Address of this article:https://073868.com/post/6081.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleRicoh Pro8320 Batch Printing Jams J032, 034