Symptom: During the printing process, the color of the copy becomes lighter and then an error SC361-01 is reported. After restarting the self-test, an error is reported. The left image shows the faulty sample, and the right image shows the repaired sample.
Reason: Fault description: TD sensor output error 1: Vt exceeds the upper limit. Fault type: Class D error.
Since it is a TD output upper limit error, this error will only be detected when the TD sensor (SEN1) detects an extremely low toner concentration.
This may occur in:
1. Incorrect detection of color powder concentration.
2. Color powder bottles cannot provide color powder.
3. Color powder cannot be supplied from the secondary storage hopper.
Solution:
1. Check the Vt value SP3210 and gamma value SP3630 of the TD output of the developer. Enter maintenance to check the current values of SP3210: Vt>4.7, and SP3630: gamma<0.3, indicating that the amount of toner in the developer is very low. Pull out the developer to check the inlet situation, and the toner is almost empty, indicating that the sensor has detected no problem. It is necessary to investigate the upstream powder path of the developer.
2. Check the toner bottle device: Take out the toner bottle and observe that there is no abnormality in the toner drive plate, and the screen displays the toner label normally. The powder bottle supply unit has no abnormalities and needs to be further investigated for the powder supply motor and auxiliary powder storage unit.
3. Check the secondary powder bin and powder discharge pipeline: Open the upper cover of the powder bin and the back cover of the machine to check the secondary powder bin [A] and the sensor [B] for used up powder (if the sensor is abnormal, even if the powder is empty, it still detects powder)
Upon inspection, it was found that the color powder in the warehouse was full and the sensor surface was intact and undamaged. Continue to check the operation of the powder supply motor. Entering the maintenance operation SP3050, a clicking sound was heard. The powder supply gear could not operate normally under the drive of the motor. The linkage gear was removed, and the manual rotation of the powder rod had high resistance and could not rotate. At this time, it was determined that the powder pipeline was blocked. The machine was shut down and the auxiliary powder bin drainage pipeline was dismantled.
It has been confirmed that the blockage of the secondary powder bin pipeline caused by the agglomeration of toner resulted in the inability to reach the developer. After thorough cleaning, the installation was resumed. The machine automatically replenished the toner during self inspection. After self inspection, the value of SP3210 was checked and found to be 2.31. The value of SP3630 was found to be 1.21, which returned to the normal range. Continuously printing test copies to restore normal concentration, TD output and development gamma values remain stable, and the fault has been resolved.
Repair Summary:
The entire process is an overall idea of this maintenance judgment. In order to quickly locate the fault point on site, after confirming that the developer toner is empty, the machine back cover can be opened to directly perform the SP3050 powder replenishment test. Observing the working status of the secondary powder bin drive gear at the back can quickly lock the fault point