Ricoh D3344C startup report code E-12

Come back soon. 342 0

Symptom: DD3344C startup report E-12

The paper compression of this model is driven by the compression motor A through the gear B to drive the shaft F, which in turn drives the compression plate to rotate and compress the waste paper through the hanging brackets and tension springs on both sides. Sensors C and D check the original position of the compression plate and whether the waste paper is full. E-12 is a compressed version that has not left or returned to its original position within the specified time.

Measure: 1. Output the detection plate paper unloading motor and compression plate motor, observe the quality of the motor, and at the same time, test other motors to determine whether the original board does not have 24V output. 2. Check that the unloading motor is functioning and the position of the compression plate has not changed, which can rule out motor and drive circuit faults. 3. Check the mechanical components and find that there are no tension springs on the drive arms at both ends of the drive shaft. An elongated and deformed tension spring was found on the paper output component of the machine.

Solution: Reinstall the intact tension spring and troubleshoot.

Tags: #E-12 #3344C #2433 #Waste cardboard #extension spring