Symptom: The copied and printed images are shallow.
Maintenance process:
1. Printing the counter page clearly shows a shallow image.
2. Check SP3-210, the output value is 3V, and the toner content in the developing unit is low.
After implementing mandatory powder replenishment, there is a significant change in the image, indicating that the powder replenishment mechanism of the machine is normal. After continuously copying multiple pages, the image continues to become lighter.
4. Check SP3-630-001 (ID sensor output), the value is 0.23V, indicating that the concentration of the sample on the drum is already very deep.
5. Continue to force powder replenishment, the image darkens, check SP3-210, the output value is 2.7V, indicating that the TD sensor is normal. Therefore, the problem point is placed on the ID sensor. When checking the ID sensor, it was found that its surface was covered by toner. After cleaning, SP3-320 (ID sensor initialization) and SP3-011 were re executed, and the results showed success, with VSP=0.59V. Re open and close the front door, and the machine has powder replenishment action. After completing the powder replenishment, the printed image is normal.
6. Continuously copied 100 pages, and the machine did not show any shallow images. The output value of SP3-210 was checked to be 2.36V, and the output value of SP3-630-001 was 0.4V. Later, the customer was called to inquire about the machine's condition, and no shallow printing occurred. The fault was resolved.
The following picture is taken after removing the transfer roller
Solution: Clean the ID sensor, perform ID sensor initialization and manual process control again to resolve the issue.
Tags: #Shallow image #Transfer roller #2555 #ID sensor #3055