Symptoms: The printed image is normal, but there is compression in some parts of the copied image, whether it is fed by a document feeder or placed on the glass of the document table. When using an A4 original, horizontal feeding, the compressed position is about 3 centimeters near the edge of the operator's side of the document table, with an area of about 4-5 millimeters (in the direction of the scanning frame movement). The image is compressed to about 60% to 70% of the original image, and when directly feeding the A4 original, the copied image is normal; Replace the scanning unit components, but the fault persists.
Analysis reasons: 1. From the fault image sample, it can be seen that the image is locally distorted, while the printed image is normal, indicating that the fault is related to scanning; 2. Whether using a document feeder to send documents or placing documents on the glass of the document table, this phenomenon occurs, indicating that there is a problem with the hardware or image processing of the scanning unit; However, even after replacing the scanning unit components, the fault persists, indicating that this issue is not caused by the hardware of the scanning unit; 3. Scanning image processing data is incorrect; 4. Firmware issues and problems with the IPU board. Measures: Attempt to adjust the scanning distortion by executing SP4-871-002 (enter numbers 0-7, observe the effect), which can adjust the copied image to be normal. Solution: Adjust the scanning distortion and execute SP4-871-002 (enter numbers 0-7, observe the effect) until the copied image is normal. |
268
0
Address of this article:https://073868.com/post/3260.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleRicoh MP6055SP appears with code SC819
NextEpson PLQ-20K-PLQ-20KM-LQ-90KP stylus printer repair manual