Ricoh MP2852 boot screen without display

Visitor 280 0
Symptoms
After an Aficio MP2852 is turned on, there is no action. Only the power light in the upper right corner of the operation panel is on. The power board, BCU, controller board and high-voltage board (removed from the new machine) have been replaced, and the fault remains. (In addition, the same failure occurs after the above-mentioned tested board is installed back to the original machine)

Reason
Usually, the above failure phenomenon is due to the short circuit of 24V or 5V load inside the machine, which causes the insurance on the power supply board to open circuit, thus causing the output of the power supply board to be abnormal. At this time, the short circuit point must be found, and the good board must not be used for computer testing, otherwise the insurance on the power supply board and even other boards will still be burned.

Solution
The process is as follows:
1) Measure each output interface of the power supply board and find that the 5V of 11 and 12 (yellow line in the figure below) of CN293 has no output, and the two 5V are the control voltages of BCU and IPU respectively


2) Measure the FU7 fuse next to CN293 and find that FU7 is open (the fuse is open in the red circle in the above figure, and there is no response when starting up)
3) Re-weld the new FU7 fuse, unplug all loads (black plugs) on the BCU board, turn on the panel and then the alarm light, indicating that the above loads include short circuit points;
4) When the TD sensor connection plug is plugged back into CN327 (in the red circle in the figure below), the machine cannot start again and the panel is not bright. Pull out the PCU unit, measure the TD connection line, and find that the CN327-1 5V output is grounded;


5) Check along the TD connecting line and find that the outer plastic bracket of the first paper feed clutch presses the connecting line, causing the outer skin of the connecting line to be damaged (see the figure below);


6) Use insulating tape to wrap the damaged part, re-weld the new FU7 insurance, and start normally after starting up.

Tags: #No display #Panel #2852 #3352