Ke Mei BH 287,367 Print Pink

Visitor 374 0
[Description] (Copy printing is almost blank, TCR value is always 0, machine does not add powder action, manual TCR powder feeding fault still exists)

Phenomenon)
1. By confirming the maintenance mode status - level history 1, it was found that the TCR-K value remained at 0
2. Adjust the TCR toner supply through maintenance mode imaging processing and check that the TCR-K value remains unchanged at 0.
Reason: After investigation, it was confirmed that the powder used by the customer was a substitute powder, which resulted in incorrect TCR chip values.
On site measures include replacing the original powder box, emptying the residual powder in the secondary powder bin, and replacing the newly ordered developing unit to restore normal operation of the machine.


According to the maintenance manual, the prerequisite for the machine to perform TCR automatic adjustment is only when it is determined that the developing unit is new, which means that the developing unit must be a newly ordered unit that has not been installed before TCR automatic adjustment can be performed.

Tags: #287 #Print light #No powder #TCR chip #367

Leave a comment