Ricoh MP2014AD machine prompts to replace the print box

Visitor 358 0
The MP2014AD machine screen showed that the print box had been replaced, and the machine counter was 499 sheets. After executing SP5-801, the machine displayed normally. When printing the counter sample, it was found that there were obvious protrusions on the lines on the sample, and the image density was very high.Upon checking the data in SP2-220, it was found that the vsp data was 2.38, indicating that the density of the sample image detected by the machine during sample production was too low, which contradicts the previously printed counter sample with a high density.

Maintenance process:
1. A new carrier was replaced and SP2-801 was executed. The printing counter sample had the same high concentration as before, and the visible vsp data 2.09 in SP2-220 was still very high.
2. The faults still exist after replacing the OPC drum, ID sensor, motherboard, and high-voltage board separately. The vsp data is always above 2.0, and the image density is always high. Moreover, since replacing the new carrier, the machine has reported replacing the print box for 1-2 printed samples.
Replace the entire PCDU for testing, troubleshoot, and the data returns to normal. However, after replacing the drum core, charging roller, developing roller, and TD sensor for testing, the fault still exists, and the VSP data is still above 2.0. It can be seen that the problem is not with the machine, nor is it related to the drum core, charging roller, developing roller, or TD. But checking the charging contact terminals behind the PCDU also showed no obvious abnormalities