Ricoh MP3353SP stuck in the fixing outlet

Visitor 409 0
MP3353SP has paper jams in each task, with the paper stuck halfway out of the output area. Despite replacing the fixing unit and BICU board, the fault persists.
Cause analysis
1. Through SP7507 inspection, it was found that the paper jam codes were all 057 (misalignment error), but the SP input detected that the alignment sensor was normal with changes in the 0 and 1 digits.
2. According to the instructions and fault situation of the cardboard code 057, it is suspected that the sensitivity of the sensor is incorrect. The positioning sensor was replaced for testing and the fault was eliminated.
Solution
Replace the alignment sensor.
Note: It is recommended that during on-site maintenance and inspection, in addition to using SP codes for testing, it is also necessary to combine the explanation of each SP code and the detection and judgment of fault conditions.

Tags: #Paper jam #Fixing #3353