[Symptom]: During the copying and printing process of the machine, the E021-0002 code may suddenly appear irregularly. After shutting down, the fault code disappears, and after copying and printing again, the error code may appear irregularly again [Failure Analysis]]: The error that occurred in E021-0002 is a developer motor error The corresponding measure is to manually rotate the gears of the main drive unit to check if they can rotate a. If it cannot rotate, replace the main drive unit b. If it can rotate, check the wiring harness between the developer motor and the DC controller circuit board 2. Use a multimeter to measure the two ends of the fuse on the low-voltage power board a. If the measured value is less than 1 ohm (conductive state) 1. Replace the developer motor 2. Replace the DC controller circuit board If the measured value is greater than 1 ohm (non-conductive state), replace the low-voltage power board maintenance process] 1. When turned on, the fault reappeared with about 100 sheets of paper. After turning off and restarting, the fault did not occur, but about 200 sheets of paper were output again 2. Rotate the main drive unit gear by hand smoothly without feeling excessive load 3. Remove the developer and check for poor contact and carrier leakage at the high-voltage developer contacts. No abnormalities were found, and shake left and right evenly during installation 4. Check the wiring harness between the developer motor and the DC controller circuit board, and no abnormalities were found 5. Measure the fuse of the low-voltage power board with a multimeter and no abnormalities are found 6. Enter maintenance mode and perform a PART-CHK test on MTR's item 09 (M10) developing motor. The test shows NG and the developing motor does not rotate. 7. Warranty low-voltage power board. After one week, replace the low-voltage power board. The machine ran for about 500 cycles, but the fault did not appear. Finally, the fault was resolved Note: When encountering this error prompt, it may also be a problem with the accumulation of the developer carrier. You can manually shake the carrier, rotate the drive wheel, observe that the stirring rod is normal, and then perform COPIER>FUTURE>INSTALL>STIR-4 on the machine, and then perform the image "complete adjustment" to restore normal operation |
403
0
Address of this article:https://073868.com/post/5966.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleCanon copier SMB scan set up multiple send setup steps