Ricoh MP3055SP powder leakage during toner transfer

Visitor 376 0
During the transportation of Ricoh MP3055SP toner, there was powder leakage,MP_2555SP_3055SP_3555SP_4055SP_5055SP_6055SP
MP3055SP toner leakage during transportation. As shown in Figure (1), there are obvious powder leakage marks on the back of the controller box


Cause analysis
1. Remove the powder supply unit and open the seal on the powder storage hopper at the red circle in Figure (2) to determine the location of the powder leakage.


2. According to Figure (2), it is determined that the arching of the lower powder spring is the main reason for the powder leakage caused by the opening of the upper seal. The correct position of the powder spring is shown in Figure 3 and Figure 4


3. Reason for the arching of the powder spring:
(1) The accumulation of toner in the toner hopper causes abnormal displacement of the spring;
(2) If the toner hopper has been disassembled before, there is still a possibility that the powder spring has not been installed properly.
Solution
Option 1: Clear the powder path and ensure that the relevant color powder conveying coils can operate normally. Reinstall the powder spring and reseal the seal.
Option 2: Replace the entire set of powder supply unit components.

Note:
Before reinstalling the powder spring, try to correct the deformation of the spring as much as possible, as shown in Figure (4) where the spring has already deformed. After installing the lower powder spring, rotate the color powder coil in Figure (4) to confirm that the lower powder spring can move up and down normally.