SC272-01 malfunction occurred after starting Ricoh C2001

Visitor 352 0
Symptoms
SC272-01 malfunction occurred after the machine was started.

Reason
1) The machine's motherboard BICU is faulty.
2) The laser unit of the machine is faulty.
3) The LDB-BICU wiring harness and connection of the machine are poor.
4) The corresponding motherboard and laser of the machine are experiencing moisture issues.

Maintenance process
On-site maintenance measures:
1) Disassemble and organize the machine motherboard BICU, LDB-BICU wiring harness connection positions. The fault cannot be eliminated by starting the machine for detection.
2) Replace the machine motherboard BICU, but the fault still persists.
3) Replace the laser unit of the machine. Troubleshooting. (Note: After disassembling the laser unit and inspecting the surface, there was no obvious moisture. Later, a hair dryer was used to blow away the moisture inside the laser, and the machine was installed and tested to be normal.)
Solution
Use a hair dryer to blow out moisture inside the laser, and the machine test is normal.
(It is recommended that customers change the location of the machine to avoid malfunctions caused by moisture)

Tags: #SC272-01 #SC272 #BICU #Laser Unit #C2001