Ricoh MC2000 printing and copying does not have a blue (blue) color fault

Visitor 345 0
Symptoms
There is no blue color issue with machine printing and copying.



Reason
1) The laser unit of the machine is not good.
2) The blue PCDU of the machine is defective.
3) The ITB transfer unit of the machine is defective.
4) The blue PCDU connection port and related wiring harness of the machine are faulty.

Maintenance process
On site maintenance measures: 1) Disassemble and inspect the relevant blue PCDU connection harness and wire connectors of the main machine.
Check and clean the laser unit, ITB unit, and blue PDCU unit of the cleaning machine. The fault cannot be eliminated by starting the machine for detection.
2) Replace the green PCDU unit and ITB unit of the machine, but the fault still exists.
3) Replace the laser unit of the machine. Troubleshooting. (Disassemble and inspect the position and related aspects of the reflector inside the laser unit, only replace the laser unit, the machine is normal)
Solution
Replace the laser unit of the machine, and the machine test is normal.

Tags: #Blue PCDU #Transfer Unit #Laser Unit #c2000 #rearview mirror