Ricoh IMC2000-C6000 Process Control Results Interpretation and Detailed Description

Visitor 307 0
Interpretation and Detailed Explanation of IMC2000-6000 Process Control Results Process Control: SP3-011After executing process control, it can be achieved through SP3-012 View the results of the last ten executions. Please refer to the following for specific interpretation of the results.
*SP3-012 Display Results Details
CategorygenerationcodeResult NameDescription
00 and higher values00not executeFactory default settings(SP default value
10 or higher values (normal)11Success-


20 and higher value ID sensors
21ID sensor Vsg adjustment errorVsg=4.0 ± x.x [V/gear] out of range
22ID sensor LED adjustment errorIfsg>maximum value
23ID sensor output error (positive reflection)Vsg.regular<最小值(最大值)
24ID sensor output error (diffuse emission)Vsg.diffusion<最小值(最大值)
25ID sensor offset voltage error (positive reflection)Voffset_ General>Maximum Value
26ID sensor offset voltage error (diffuse reflection)Voffset_ diffusion>maximum value




45 and higher value ID pattern detection
45ID pattern extraction errorUndetectableID pattern
50Vmin_Sk/K2 error (maximum value)K:Vmin_Bk/CMY:K2<最大值
51Vmin_Sk/K2 error (minimum value)K:Vmin_Bk/CMY:K2<最小值
52K5 error (maximum value)K5>maximum value
53K5 error (minimum value)K5>minimum value
54Approximate point error in K5 calculationApproximate points for K5 calculation<最小值
55Gamma error in development (maximum value)Developing Gamma<最大值
56Gamma error in development (minimum value)Developing Gamma<最小值
57Start developing voltage:Vk error (maximum value)Start developing voltage:Vk<最大值
58Start developing voltage:Vk error (minimum value)Start developing voltage:Vk<最小值
59Lack of sufficient valid dataAdhesive for developing gamma calculation pointsThe quantity data is lower than2

60 and higher potential adjustment
61LD not lit upnot writtenP pattern.
62Remaining potential:Vr errorVr>maximum value
63Potential:Vd adjustment errorUnable to adjust within the target rangeVd。
64Exposure potential:Vpl adjustment errorUnable to adjust within the target rangeVpl
Results of 90 and higher values(End)90Unadjusted potentialThe potential control method is set as[0: Fixed]
99cut offCut off through door opening, power off, errors, etc. (Set during execution)Set.)

Interpretation of Process Control Results
  • Execution result sample (according toYMCK order starts from the left)
  • Factory default value(SP default value: [00,00,00,00]
  • Start adjusting:[99,99,99,99]
  • Failure Vsg adjustment (Y): [21,99,99,99] (Example)
  • Maximum gamma value for development(C) Error: [99,99,55,99] (Example)
  • success:[11,11,11,11] (Example)


20 and larger ID sensors:If this type of result code appears, you can try cleaning or replacing itID sensor, check the transfer unit
45 and higher value ID pattern detection:If this type of result code appears, you can try clearing or replacing itID sensor, BCU board
60 and higher potential adjustment:If this type of result code appears, you can try replacing the high voltage test
Results of 90 and higher values (end):If this type of result code appears, you can try replacing the power supply and checking the door switch

Tags: #process control #C3000 #C2500 #c6000 #Sensor Vsg