Ricoh IMC2000-C6000 Line Position Adjustment Results Interpretation and Detailed Description

Come back soon. 357 0

Interpretation of IMC2000-6000 line position adjustment and VSG adjustment results: Line position adjustment can be viewed through SP2-194-010-012 after SP2-111 line position adjustment. Please refer to the following content for specific interpretation of the results. Line position adjustment results SP2-194-010~-012 (line position adjustment results: C, M, Y) This SP displays the number of line position adjustment results on the LCD. Simultaneously displaying colors with errors (M, Y, or C).

Serial numberresultDescriptionNote
0unfinishedThe line position adjustment has not been completed yet.-
1Successfully completedCorrectly adjust the line position.-
2Unable to detect patternThe ID sensor did not detect the image used for line position adjustmentLike.Please refer to the backupNote
3The lines on the pattern are higher than the target valuefewThe pattern detected by the D sensor is not sufficient for adjusting the line positionWhole.Please refer to the backupNote
4The lines on the pattern are higher than the target valuemanyNot used in this machine.-
5-9Unused--


Detailed Explanation of Line Position AdjustmentWhen there is a color alignment error on the output, perform line position adjustment as follows.

  • For this adjustment, please use A3/DLT Size paper.


Line position adjustment1. Execute SP2-111-003 (mode c: coarse adjustment).2. utilizeSP2-194-007 Check if the adjustment result of the line position is correct(0: Successfully completed,1: Unfinished)If the result is“1”Please refer to the 'Countermeasure Table for Color Alignment Errors'.3. ExecuteSP2-111-001 (Mode a: Fine tune twice).4. utilizeSP2-194-007 Check if the adjustment result of the line position is correct(0: Successfully completed,1: Unfinished)If the result is“1”Please refer to the 'Countermeasure Table for Color Alignment Errors'.5. Place a few A3/DLT sheets on the hand fed paper tray Paper.

  • When printing test patterns, please use a hand fed paper tray to feed the paper.

6. utilizeSP2-109-003 Print out the test pattern“7”。7. Use a small magnifying glass to inspect printed copies.8. If there is no color alignment error on the output, then the line position adjustment has been performed correctly. If an error occurs, please refer toCountermeasure Table for Color Alignment Errors.
Countermeasure Table for Color Alignment ErrorsExecuteAfter SP2-111-003

  • Result:SP2-194-007 in“1”

  • Result:SP2-194-010、-011、-012 in2 "or" 3 "(line pattern detection failed)

Test pattern inspectionPossible reasons/Countermeasures
Image whitening, abnormal image, low density
  • Poor image processing unit

  • The concentration of the test pattern is low

  • Bad controller

1. Replace the high-voltage power supply unit2. Implement mandatory process control(SP3-011-001) or supply oneSome color powder(SP3-015-xxx)3. ReplaceBCU。
The image is normal, but there is a color alignment error
  • ID sensor malfunction

  • BCU defect

1. Replace the ID sensor2. Replace the BCU.

ExecuteAfter SP2-111-003

  • Result:SP2-194-007 in“1”

  • One of the results:SP2-194-010、-011、-012 in“4 "(out of adjustable range)

Test pattern inspectionPossible reasons/Countermeasures
M. The main scan alignment of C and Y is offset from the main scan alignment of K by more thanpass±15 mm。
  • Bad laser unit

  • BCU defect

1. Replace the laser unit2. Replace the BCU.
M. The sub scan alignment of C and Y is offset from the sub scan alignment of K by more thanpass±20 mm。
  • Poor image transfer belt

  • Poor driving unit

  • BCUbad

1. Replace the image transfer belt2. Replace the drum motor3. Replace the BCU.
Main scan alignment offset exceeds± 0.66mm, but only on the output componentThe central area of the image.
  • centerID Poor sensor

  • Deformation of the central area on the image transfer belt

  • BCU bad

1. ReplaceID Sensors,2. Replace the image transfer belt.3. ReplaceBCU。
M. C and Y deviate from the main scan of K by more than ± 0.75 mm
  • PCU bad

  • Bad laser unit

  • BCU bad

1. Reinstall or replace BCU2. Replace the laser unit.3. ReplaceBCU。
Other
  • Skew correction upper limit error

  • BCU bad

  • Bad laser unit

1. Replace BCU2. Replace the laser unit.


Execute
After SP2-111-003

  • Result:SP2-194-007 in“1”

  • Result:SP2-194-010、-011、-012 in“0”。

Test pattern inspectionPossible reasons/Countermeasures

ExecuteSP2-111-001 or -002.

ExecuteAfter SP2-111-001

  • Result:SP2-194-007 in“1”

  • Result:SP2-194-010、-011、-012 in2 "or" 3 "(line pattern detection failed)

Test pattern inspectionPossible reasons/Countermeasures
Image whitening, abnormal image, low density
  • Poor image processing unit and low concentration of test patterns

  • BCU bad

1. Replace the high-voltage power supply unit.2. Implement mandatory process control(SP3-011-001) or supply oneSome color powder(SP3-015-xxx)。3. ReplaceBCU。
The image is normal, but there is a color alignment error
  • ID sensor malfunction

  • BCU defect

1. Replace the ID sensor2. Replace the BCU.

ExecuteAfter SP2-111-001

  • Result:SP2-194-007 in“1”

  • Result:SP2-194-010、-011、-012 in4 "(out of adjustable range)

Test pattern inspectionPossible reasons/Countermeasures
The image density on the output is low
  • Low pattern density

Implement mandatory process control(SP3-011-001) or supply some color powder (SP3-015-xxx).
M. The main scan alignment of C and Y is offset from the main scan alignment of Kexceed±1.4 mm。
  • No component defects, laser optical cavity unit defects

  • BCU bad

1. Execute SP2-111-003 again2. Replace the laser unit.3. Replace the BCU.
M. The sub scan alignment of C and Y is offset from the sub scan alignment of Kexceed±1.4mm。
  • No defective components

  • Poor image transfer belt

  • Poor driving unit

  • BCU defect

1. Execute SP2-111-003 again2. Replace the image transfer belt.3. Replace the drum motor4. Replace the BCU.
Main scan alignment offset exceeds± 0.66mm, but only on the output componentThe central area of the image.
  • centerID sensor malfunction

  • Deformation of the central area on the image transfer belt

  • BCU defect

1. Replace the ID sensor2. Replace the image transfer belt3. Replace the BCU.
M. C and Y deviate from the main scan of K by more than ± 0.75 mm.At the end of the scanning line?
  • PCDU malfunction

  • Bad laser unit

  • BCU defect

1. Reinstall or replace the PCDU2. Replace the laser unit.

3. Replace the BCU.
Other
  • Skew correction upper limit error

  • BCU defect

  • Bad laser unit

1. Replace BCU2. Replace the laser unit.


ExecuteAfter SP2-111-001

  • Result:SP2-194-007 in“0”

  • Result:SP2-194-010、-011、-012 Mid color alignment error

Test pattern inspectionPossible reasons/Countermeasures
The main scan of K is offset in alignment.
  • SP for main scanning Abnormal setting value:K

utilizeSP2-101-001 Adjust this value.
The main scanning length of K is offset.
  • SP for main scan length detection Abnormal setting value:K

utilizeSP2-102-001 and -003 adjust this value. Note: The settings for these SPs should be the same.


ExecuteAfter SP2-111-001

  • Result:SP2-194-007 in“0”

  • Result:SP2-194-010、-011、-012 Color alignment error in the middle

Test pattern inspectionPossible reasons/Countermeasures
The image density on the output is low
  • Low pattern density

Implement mandatory process control(SP3-011-001) or supply some color powder (SP3-015-xxx).
The main scan is offset in alignment, but only in the central area of the output image.
  • centerID Poor sensor

  • Deformation of the central area on the image transfer belt BCU

1. Replace the ID sensor,2. Replace the image transfer belt.3. Replace the BCU.

bad
M. The main scanning alignment of C and Y is offset.
Laser optical cavityUnit malfunction
  • ID sensor malfunction

  • BCU defect

  • SP value error

1. Replace the laser optical cavity unit,2. Replace the ID sensor.3. Replace the BCU,4. Adjust using SP2-182-004 to -021This value.
M. The secondary scanning of C and Y is offset in alignment.Poor image transfer belt
  • Poor driving unit

  • ID sensor malfunction

  • BCU defect

  • SP value error

1. Replace the image transfer belt, 2 Replace the ID sensor.3. Replace the drum motor, 4 Replace BCU.5. Use SP2-182-022 to -039 to adjust this value.
M. The skewness of C and Y is different.
  • PCDU malfunction

  • Poor laser optical cavity unit

  • BCU bad

1. Reinstall or replace the PCDU2. Replace the laser optical cavity unit.3. Replace the BCU.
The secondary scanning line is offset. The offset line is in a cyclic state.
  • PCDU malfunction

  • Poor driving unit

  • Drum phase adjustment error


1. ExecuteSP1-902-001 (drum phase adjustment);Regarding details Please refer to replacement and adjustment for details - Drive unit - Gear unitYuan.2. Reinstall or replace the PCDU.3. Check or replace the drive unit.