Interpretation of IMC2000-6000 line position adjustment and VSG adjustment results: Line position adjustment can be viewed through SP2-194-010-012 after SP2-111 line position adjustment. Please refer to the following content for specific interpretation of the results. Line position adjustment results SP2-194-010~-012 (line position adjustment results: C, M, Y) This SP displays the number of line position adjustment results on the LCD. Simultaneously displaying colors with errors (M, Y, or C).
| Serial number | result | Description | Note |
| 0 | unfinished | The line position adjustment has not been completed yet. | - |
| 1 | Successfully completed | Correctly adjust the line position. | - |
| 2 | Unable to detect pattern | The ID sensor did not detect the image used for line position adjustmentLike. | Please refer to the backupNote |
| 3 | The lines on the pattern are higher than the target valuefew | The pattern detected by the D sensor is not sufficient for adjusting the line positionWhole. | Please refer to the backupNote |
| 4 | The lines on the pattern are higher than the target valuemany | Not used in this machine. | - |
| 5-9 | Unused | - | - |
Detailed Explanation of Line Position AdjustmentWhen there is a color alignment error on the output, perform line position adjustment as follows.
For this adjustment, please use A3/DLT Size paper.
Line position adjustment1. Execute SP2-111-003 (mode c: coarse adjustment).2. utilizeSP2-194-007 Check if the adjustment result of the line position is correct(0: Successfully completed,1: Unfinished)If the result is“1”Please refer to the 'Countermeasure Table for Color Alignment Errors'.3. ExecuteSP2-111-001 (Mode a: Fine tune twice).4. utilizeSP2-194-007 Check if the adjustment result of the line position is correct(0: Successfully completed,1: Unfinished)If the result is“1”Please refer to the 'Countermeasure Table for Color Alignment Errors'.5. Place a few A3/DLT sheets on the hand fed paper tray Paper.
When printing test patterns, please use a hand fed paper tray to feed the paper.
6. utilizeSP2-109-003 Print out the test pattern“7”。7. Use a small magnifying glass to inspect printed copies.8. If there is no color alignment error on the output, then the line position adjustment has been performed correctly. If an error occurs, please refer toCountermeasure Table for Color Alignment Errors.
Countermeasure Table for Color Alignment ErrorsExecuteAfter SP2-111-003
Result:SP2-194-007 in“1”
Result:SP2-194-010、-011、-012 in2 "or" 3 "(line pattern detection failed)
| Test pattern inspection | Possible reasons/Countermeasures |
| Image whitening, abnormal image, low density |
|
| The image is normal, but there is a color alignment error |
|
ExecuteAfter SP2-111-003
Result:SP2-194-007 in“1”
One of the results:SP2-194-010、-011、-012 in“4 "(out of adjustable range)
| Test pattern inspection | Possible reasons/Countermeasures |
| M. The main scan alignment of C and Y is offset from the main scan alignment of K by more thanpass±15 mm。 |
|
| M. The sub scan alignment of C and Y is offset from the sub scan alignment of K by more thanpass±20 mm。 |
|
| Main scan alignment offset exceeds± 0.66mm, but only on the output componentThe central area of the image. |
|
| M. C and Y deviate from the main scan of K by more than ± 0.75 mm |
|
| Other |
|
ExecuteAfter SP2-111-003
Result:SP2-194-007 in“1”
Result:SP2-194-010、-011、-012 in“0”。
| Test pattern inspection | Possible reasons/Countermeasures |
| ExecuteSP2-111-001 or -002. |
ExecuteAfter SP2-111-001
Result:SP2-194-007 in“1”
Result:SP2-194-010、-011、-012 in2 "or" 3 "(line pattern detection failed)
| Test pattern inspection | Possible reasons/Countermeasures |
| Image whitening, abnormal image, low density |
|
| The image is normal, but there is a color alignment error |
|
ExecuteAfter SP2-111-001
Result:SP2-194-007 in“1”
Result:SP2-194-010、-011、-012 in4 "(out of adjustable range)
| Test pattern inspection | Possible reasons/Countermeasures |
| The image density on the output is low |
|
| M. The main scan alignment of C and Y is offset from the main scan alignment of Kexceed±1.4 mm。 |
|
| M. The sub scan alignment of C and Y is offset from the sub scan alignment of Kexceed±1.4mm。 |
|
| Main scan alignment offset exceeds± 0.66mm, but only on the output componentThe central area of the image. |
|
| M. C and Y deviate from the main scan of K by more than ± 0.75 mm.At the end of the scanning line? |
|
| 3. Replace the BCU. | |
| Other |
|
ExecuteAfter SP2-111-001
Result:SP2-194-007 in“0”
Result:SP2-194-010、-011、-012 Mid color alignment error
| Test pattern inspection | Possible reasons/Countermeasures |
| The main scan of K is offset in alignment. |
|
| The main scanning length of K is offset. |
|
ExecuteAfter SP2-111-001
Result:SP2-194-007 in“0”
Result:SP2-194-010、-011、-012 Color alignment error in the middle
| Test pattern inspection | Possible reasons/Countermeasures | ||
| The image density on the output is low |
| ||
| The main scan is offset in alignment, but only in the central area of the output image. |
| bad | |
| M. The main scanning alignment of C and Y is offset. | Laser optical cavityUnit malfunction |
| |
| M. The secondary scanning of C and Y is offset in alignment. | Poor image transfer belt |
| |
| M. The skewness of C and Y is different. |
| ||
| The secondary scanning line is offset. The offset line is in a cyclic state. |
| ||
| 1. ExecuteSP1-902-001 (drum phase adjustment);Regarding details Please refer to replacement and adjustment for details - Drive unit - Gear unitYuan.2. Reinstall or replace the PCDU.3. Check or replace the drive unit. |
Tags: #c6000 #C2500 #C3000 #Line position adjustment #VSG