Ricoh IMC2000-C6000 VSG Adjustment and TD Sensor Initialization Results Interpretation

Visitor 319 0
Interpretation of IMC2000-6000 VSG adjustment and TD initialization results
VSG adjustment: SP3-320-001Execute VSG After adjustment, it can be achieved through SP3-321-001-003 View the execution results. Please refer to the following for specific interpretation of the results.The displayed numbers represent the results of each sensor inspection.There are three ID sensors on the ID sensor board, divided into front, middle, and back according to their distance from the operator.000=FCR (F: Front end, C: Middle, R: Back end)*SP3-323 Display Results Details
CodeResult NameDescription
0not execute(SP default value)
1Success-
2ID sensor calibration errornot inVsg=Vsg.reg (target value) ± x.x [V/level] range
3Offset voltage errorVoffset_ General>Maximum Value or Voffset_ Diffusion>Maximum Value
4The maximum value of the LED power supply is incorrect.Ifsg>maximum value
5ID sensor output error.Vsg< Vsg_常规(错误)
9cut offThe door was opened incorrectly, resulting in a power outage.

Interpretation of VSG adjustment resultsID sensor calibration error: Perform the following operations to test1. CleaningID sensor.2. CheckITB cleaning unit. Clean or replace the image transfer belt.3. Replace the image transfer belt.4. ReplaceID sensor.5. Check the connection.6. ReplaceBCU board.
ID sensor output error: Perform the following operations to test1. ReplaceID sensor.2. Check the connection.3. ReplaceBCU board.
InitializationTD Sensor: SP3-030(001: Execute all, 002: Execute COL (color), 003: Execute K (black), 004: Execute C (cyan), 005: Execute M (magenta), 006: Execute Y (yellow). After initializing the TD sensor, it can be done through SP3-031-001 query results
*SP3-031-001 Display Results DetailsThe displayed numbers represent the initialization results of each developer.0000 = YMCKWhen encountering initialization TD When the sensor fails, it can be based on SP3-031-011 Replace the relevant components based on the numerical valuesClean to troubleshoot issues.
Serial numberresultDescriptionPossible reasons/Measures taken
1Successfully completedSuccessfully completed developer initialization.-
2Force terminateForcefully terminate developer initialization.During initialization, the cover plate is opened or the main switch is closed.1. AtSP When completed in mode, execute the developer againinitialization. If the results are the same, reinstall the engine Main firmware.When the unit replacement is completed, turn off and then turn on the main switch againClose it.
6Vt errorWhen Vcnt is 4.3 V, Vt is less than 0.7 V.1.TD sensor malfunction
7Vcnt Error 1When Vcnt is a Vt target of ± 0.2V, Vcnt is 4.7V larger.1.2.3.TD sensor malfunctionVt The target setting value is incorrect.Color powder concentration error
8Vcnt Error 2When Vcnt is 4.3 V, Vt is less than 0.7 V;When Vcnt is Vt target ± 0.2V, Vcnt is greater than 4.7V.1.TD sensor malfunction
9Vcnt Error 3Vcnt is Vt target ± greater than 0.2V.1.2.3.TD sensor malfunctionVt The target setting value is incorrect.Color powder concentration error