Symptoms When SC370 (TM (ID) sensor calibration error) is displayed Possible causes: Missing/incorrect connection of TM/ID sensor connector TM/ID sensor detection window is dirty TM/ID sensor fault ITB fluctuation or belt slip Solution: Turn off and then turn on the power, check if SC appears. If SC appears again, perform the following steps. 1. Check if all connectors related to TM/ID sensors are securely connected. If the connector is disconnected or loose, please reconnect it. If the TM/ID sensor is dirty, clean the sensor (do not use a dry cloth). 2. Execute SP5-804-255 (output check: paper transfer contact operation) to operate the paper transfer contact and separation motor (M18) to check the opening/closing of the blocking plate. 3. Check if there are any abnormal conditions on the surface of the image transfer belt. If any abnormal conditions are found on the surface of the image transfer belt, please replace the image transfer belt. Belt scratches, wrinkling, skewing, cleaning faults, background stains, film 4. Check if there is a fault with the TM/ID sensor (S48). If there is a defect, please restore or replace the sensor. 5. Check the wires. If the wire is disconnected or damaged, please replace it. If the SC has not been cleared after steps 1 to 6, please replace the BICU (PCB10). Recovery check steps: 1. Perform Vsg adjustment (SP3-320-001). 2. Execute SP3-323-001 (Vsg adjustment determination? Check the code for the latest update. If the code is "1": restored If the code is not "1": not restored Adjustment after recovery: After restoring SC370, perform the following adjustment steps. 1. Execute SP2-111-004 (forced line position: adjust mode d). 2. Execute the following SP and check the results: SP2-194-007 (Execution result) SP2-194-010 (Error result: C) SP2-194-011 (Error result: M) SP2-194-012 (Error result: Y) Execution result sample Factory default: 0 Success: 1 3. Execute SP3-011-001 (Manual Process Control: Execute). 4. Execute the following SP and check the results. SP3-012-001 to 010 (Front end) SP3-012-011 to 020 (Center) SP3-012-021 to 030 (backend) Execution result samples (starting from the left in YMCK order) Factory default: [00,00,00,00] Start adjusting: [99,99,99,99] Failed Vsg adjustment (Y): [21,99,99,99] Error in maximum development gamma value (C): [99,99,55,99] Success: [11,11,11] |
409
0
Address of this article:https://073868.com/post/1203.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleRicoh MP3055 prompts lack of powder after changing a new powder
NextRicoh IMC2000-C6000 VSG Adjustment and TD Sensor Initialization Results Interpretation