Product Name
Pro 8100s/8110s/8120s,Pro8200s/8210s/8220s,Pro 8300s/8310s/8320s
Symptom: Pro 8220S startup self-test report SC382-01.
Reason:
1. Upon checking the PM value, it was found that the drum had been used for 2.45 million yuan. A new drum was replaced, and 750000 yuan had been used for charging. After replacing the new charging, the carrier only used 210000 yuan and did not need to be replaced. After cleaning the drum potential and restarting the device, the fault persisted,
Solution:
2. Check that the gamma value of SP3630 is 0.66, which is too low. Turn off all process controls 1, 2, and 4 of SP3500, perform SP3050 forced powder replenishment twice, and then perform SP3011-2 and SP3011-1. Check that the gamma value of SP3630 has changed to 1.01, which is within the normal range,
3. Restore all items 1, 2, and 4 of SP3500, restart the device, pass self-test, print test, and restore the device to normal
Tags: #8200 #8120 #8300 #SC382-01 #Potential sensor