Symptoms: An MP9002SP machine cannot enter the ready state, and after waiting for a few minutes, the screen displays the fault phenomenon of SC670-00. Reason: The control panel unit is defective; BCU board malfunction; Bad motherboard; Software errors; Poor PSU-E or PSU-C; Bad paper exit sensor harness. Maintenance process: 1. Replace the control board. The NVRAM, hard drive, SD card, and memory on the control board are still faulty. 2. Replace the BCU board and IPU board, but the fault persists. 3. No abnormalities were found during the inspection of the wiring harness. 4. Upon re inspection of the faulty machine on site, the power board was checked and FU101 was found to be blown. The insurance specification is 220V5A. After replacing the 220V3A insurance for testing, the fuse will melt immediately after turning on the machine. The machine is equipped with a voltage stabilizing device. During inspection, it was not turned on to the stabilizing position, and the voltage was checked to be 236V. It is preliminarily judged that the power board was damaged due to instantaneous high voltage, and other fuses on the power board were not damaged. Fuse position As shown in the following figure.
Important reminder: Engineers must pay attention to checking the user's power supply when installing this series of machines. Solution: Replace the power board and troubleshoot. |