Reason1. Fixing unit malfunction;Maintenance process1. Inquire about the usage environment of the faulty machine being in the north, where the room temperature is too low, resulting in a decrease in the fixing temperature during use and an error message;2. After increasing the idle running time of the fixing machine, the fault did not improve;3. After replacing the thermistor, thermostat, and fixing lamp in the fixing unit, the fault still persists;4. After exchanging and testing BICU (with EPROM) and PSU, the fault still persists, and the faulty machine card is functioning normally on other machines;5. There are only 2 fixing lamps in the hot roller of this model, but there is an extra fixing lamp socket that can be added with a shadow lamp to maintain the fixing temperature;6. Adding a fixing lamp requires replacing some related parts, as shown in the following figure;
|