Symptoms The MP5055SP model frequently experiences SC992 fault codes. At the beginning, after clearing the power on and off, the SC992 code can be output for operation, and the SC992 code may appear intermittently; At present, a fault code appears immediately when performing job output after the power on/off is eliminated.
Maintenance process 1. The maintenance manual does not provide an explanation for the SC992 fault code. Please refer to the manuals of other models to explain it as a software issue. 2. Failed to rule out firmware upgrade (PowerNavigation Sys: F.L3.06.1) and package firmware package; 3. Replace the controller board, BCU board, IPU board, NVRAM, EEPROM, SOP screen, power board and other components with unchanged fault symptoms; 4. After replacing the fixing fan for testing, the fault was resolved after replacing the "fan-2". The fault did not reoccur even after replacing the original fan, and it is suspected that the poor contact of the fan plug is the cause. Solution: Reinstall the 'fixing fan-2' and troubleshoot. Special note: In this series of models, there is only one rear fixing fan for MP2555/3055/3555/4055, while MP5055/6055 models have two fixing fans. At present, the majority of inquiries about this fault code on the WeChat platform are for the MP5055 model. |
Tags: #SC992 #5055 #NVRAM #Controller board