Symptoms Fault: M2701 changes to M2700 after replacing ERPOM. Maintenance process Due to a previous malfunction, it was confirmed that the EPROM of M2701 was damaged. After replacement, the model was changed to M2700, which cannot use double-sided, but DF can be used normally. 2. Following the steps of replacing EPROM with MP2014AD, changing the parameters of SP5882-001 from 0 to 5 is ineffective. [kkpay=5]3. After consulting the maintenance manual, it was found that this model has a model code similar to A4, which is the PnP ID setting of SP5950. Try changing the value of this parameter from "1" to "2", and after restarting, print the configuration page and change the SMC model back to M2701 to troubleshoot. 4. It is now confirmed that the parameter settings for SP5950 correspond to the specific model as follows:. “1”— M 2700 “2”— M 2701 “3”— G 1027 “4”— G 1127 Solution After changing the SP5950 value to 2, the fault was resolved.[/kkpay] |
300
0
Address of this article:https://073868.com/post/3018.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleRicoh C751EX,C651 repair case