Ricoh 8300 reported the error SC202 at the same time, sc120-00

Visitor 409 0
Symptoms: Pro 8300 simultaneously reports error codes SC02-00 and 120-00

Reason:
Situation description: As shown above, the machine reported an error during standby, with the printer displaying code SC02-00 and the copier displaying code SC120-00. After restarting the machine, the customer still reported an error, so a repair notice was sent for maintenance.

Solution:
1. Preliminary review of the manual's code description for SC02-00 indicates that there is no drive signal for the polygon mirror motor. And SC120-00 is a scanner in-situ error.



After a detailed interpretation of the error causes and solutions for SC202 and 120-00 in the manual, I have identified the approximate fault points in my mind. SC202 is the multi angle mirror motor of the laser that did not start up, and the upstream BICU did not give it a start signal or 24V power supply. This code focuses on troubleshooting the connected wiring harness, BICU faults, and whether the PSU-B supplying power to BICU is faulty. )(SC120 also mentioned the connection issue between the scanner motor and BICU, as well as the failure of BICU)
3. Combining the situation of two codes, both are pointing to the connection signal, power supply, and PSU-B issues of BICU. So I opened the dot plot to see the specific power supply relationship.




4. According to the circuit diagram, it can be traced that the 24V of ADF is supplied by PSCU-B, and the 5V and start signal are provided by BICU. The 24V power supply and signal of the laser polygon mirror come from BICU. And the source of BICU's 24V is PSU-B.
5. Open the back cover of the backpack behind the machine, then turn it on and observe the power indicator light on the BICU.



After observing the startup, it was found that the power indicator light used to confirm on the BICU was on at 5V, while the 24V indicator light was off. This gave me a rough idea that the BICU was likely good, and the real problem was the PSU-B that supplied it with 24V power.



7. A 24V output plug was found on the PSU-B circuit board, and after measuring with a multimeter, it was confirmed that there was no 24V output. Routine checks have been conducted on the on/off status of all fuses on this board. If the fuses are good, it indicates that there is a problem with an electrical component on this circuit board, causing the board to malfunction


8. Replace the PSU-B circuit board with a fixed component, and after replacement, the code is eliminated and the problem is resolved.


Tags: #SC202 #SC120 #8300 #Scanner in situ #Multi angle mirror motor